SolarEdge Modbus data collection library

Programming Languages

python
139335 projects - #7 most used programming language
Makefile
30231 projects

Projects that are alternatives of or similar to solaredge modbus

ModbusMechanic
Cross platform GUI MODBUS TCP/RTU simulator & gateway. Interprets data types including ascii float and int.
Stars: ✭ 63 (+28.57%)
Mutual labels:  modbus, modbus-tcp, modbus-rtu
go-modbus
modbus write in pure go, support rtu,ascii,tcp master library,also support tcp slave.(WIP new implement<old: https://github.com/thinkgos/gomodbus >)
Stars: ✭ 124 (+153.06%)
Mutual labels:  modbus, modbus-tcp, modbus-rtu
EasyModbusTCP.Java
EasyModbusTCP library for Java implementation
Stars: ✭ 76 (+55.1%)
Mutual labels:  modbus, modbus-tcp, modbus-rtu
huawei solar
Home Assistant integration for Huawei Solar inverters via Modbus
Stars: ✭ 126 (+157.14%)
Mutual labels:  modbus, modbus-tcp, modbus-rtu
modbus-esp8266
Most complete Modbus library for Arduino. A library that allows your Arduino board to communicate via Modbus protocol, acting as a master, slave or both. Supports network transport (Modbus TCP) and Serial line/RS-485 (Modbus RTU). Supports Modbus TCP Security for ESP8266/ESP32.
Stars: ✭ 332 (+577.55%)
Mutual labels:  modbus, modbus-tcp, modbus-rtu
Pyscada
PyScada is a open source scada system that uses the Django framework as backend
Stars: ✭ 233 (+375.51%)
Mutual labels:  modbus, modbus-tcp
Jlibmodbus
JLibModbus is an implementation of the Modbus protocol v1.1b in java language.
Stars: ✭ 149 (+204.08%)
Mutual labels:  modbus, modbus-tcp
Mbusd
Open-source Modbus TCP to Modbus RTU (RS-232/485) gateway.
Stars: ✭ 233 (+375.51%)
Mutual labels:  modbus, modbus-tcp
Genmon
Generac Generator Monitoring using a Raspberry Pi and WiFi
Stars: ✭ 143 (+191.84%)
Mutual labels:  modbus, modbus-tcp
Solarthing
Monitors an Outback MATE and a Renogy Rover - MPPT Charge Controller. Integrates with Grafana, PVOutput and more!
Stars: ✭ 33 (-32.65%)
Mutual labels:  influxdb, modbus
mbmd
ModBus Measurement Daemon - simple reading of data from ModBus meters and grid inverters
Stars: ✭ 140 (+185.71%)
Mutual labels:  modbus, sunspec
Modbustool
A modbus master and slave test tool with import and export functionality, supports TCP, UDP and RTU.
Stars: ✭ 187 (+281.63%)
Mutual labels:  modbus, modbus-tcp
J2mod
Enhanced Modbus library implemented in the Java programming language
Stars: ✭ 155 (+216.33%)
Mutual labels:  modbus, modbus-tcp
arduino-modbus-rtu-tcp-gateway
Arduino-based Modbus RTU to Modbus TCP/UDP gateway with web interface. Allows you to connect Modbus RTU slaves (such as sensors, energy meters, HVAC devices) to Modbus TCP/UDP masters (such as home automation systems). You can adjust settings through web interface.
Stars: ✭ 56 (+14.29%)
Mutual labels:  modbus-tcp, modbus-rtu
solar-logger
A datalogger for a solar inverter. Stores data in influxdb and displays it in grafana. Has load diverting capability, to use the inverter's excess power
Stars: ✭ 53 (+8.16%)
Mutual labels:  influxdb, inverter
rodbus
Rust implementation of Modbus with idiomatic bindings for C, C++, .NET, and Java
Stars: ✭ 34 (-30.61%)
Mutual labels:  modbus, modbus-tcp
Modbus Tcp Client
PHP client for Modbus TCP and Modbus RTU over TCP (can be used for serial)
Stars: ✭ 89 (+81.63%)
Mutual labels:  modbus, modbus-tcp
Modbuspp
A C++ Library for Modbus TCP Protocol
Stars: ✭ 108 (+120.41%)
Mutual labels:  modbus, modbus-tcp
crc16
A native node addon to calcalate and verify CRC16 values, adopted by MODBUS agreement
Stars: ✭ 24 (-51.02%)
Mutual labels:  modbus, modbus-rtu
Regulator
DIY Arduino consumption regulator build to use excess solar power for auxiliary 'summer' heating. The solar power data are retrieved over SunSpec Modbus TCP. IoT monitoring with Blynk and local Web server.
Stars: ✭ 32 (-34.69%)
Mutual labels:  modbus-tcp, sunspec

solaredge_modbus

solaredge_modbus is a python library that collects data from SolarEdge inverters over Modbus RTU or Modbus TCP.

Installation

To install, either clone this project and install using setuptools:

python3 setup.py install

or install the package from PyPi:

pip3 install solaredge_modbus

Usage

The script example.py provides a minimal example of connecting to and displaying all registers from a SolarEdge power inverter over Modbus TCP.

usage: example.py [-h] [--timeout TIMEOUT] [--unit UNIT] [--json] host port

positional arguments:
  host               Modbus TCP address
  port               Modbus TCP port

optional arguments:
  -h, --help         show this help message and exit
  --timeout TIMEOUT  Connection timeout
  --unit UNIT        Modbus device address
  --json             Output as JSON

Output:

Inverter(10.0.0.123:1502, connectionType.TCP: timeout=1, retries=3, unit=0x1):

Registers:
    Manufacturer: SolarEdge
    Model: SE3500H-RW000BNN4
    Type: Single Phase Inverter
    Version: 0004.0009.0030
    Serial: 123ABC12
    Status: Producing
    Temperature: 49.79°C
    Current: 8.93A
    Voltage: 240.20V
    Frequency: 50.00Hz
    Power: 2141.80W
    Power (Apparent): 2149.60VA
    Power (Reactive): 183.20VAr
    Power Factor: 99.69%
    Total Energy: 3466757Wh
    DC Current: 5.68A
    DC Voltage: 382.50V
    DC Power: 2173.50W

Passing --json returns:

{
    "c_manufacturer": "SolarEdge",
    'c_model': 'SE3500H-RW000BNN4',
    'c_version': '0004.0009.0030',
    'c_serialnumber': '123ABC12',
    'c_deviceaddress': 1,
    'c_sunspec_did': 101,
    'current': 895,
    'l1_current': 895,
    'l2_current': False,
    'l3_current': False,
    'current_scale': -2,
    'l1_voltage': 2403,
    'l2_voltage': False,
    'l3_voltage': False,
    'l1n_voltage': False,
    'l2n_voltage': False,
    'l3n_voltage': False,
    'voltage_scale': -1,
    'frequency': 50003,
    'frequency_scale': -3,
    'power_ac': 21413,
    'power_ac_scale': -1, 
    'power_apparent': 21479,
    'power_apparent_scale': -1,
    'power_reactive': 16859,
    'power_reactive_scale': -2,
    'power_factor': 9969,
    'power_factor_scale': -2,
    'energy_total': 3466757,
    'energy_total_scale': 0,
    'current_dc': 5678,
    'current_dc_scale': -3,
    'voltage_dc': 3826,
    'voltage_dc_scale': -1,
    'power_dc': 21726,
    'power_dc_scale': -1,
    'temperature': 4979,
    'temperature_scale': -2,
    'status': 4,
    'vendor_status': 0
}

Note that if kWh meters or batteries are connected to your inverter, these will also be presented in the JSON output.

A second script, example_influxdb.py provides an example InfluxDB writer. It connects to an inverter over Modbus TCP, and writes inverter, battery and meter values to an InfluxDB every second.

usage: example_influxdb.py [-h] [--timeout TIMEOUT] [--unit UNIT] [--interval INTERVAL] [--influx_host INFLUX_HOST] [--influx_port INFLUX_PORT] [--influx_db INFLUX_DB]
                           [--influx_user INFLUX_USER] [--influx_pass INFLUX_PASS]
                           host port

positional arguments:
  host                  Modbus TCP address
  port                  Modbus TCP port

optional arguments:
  -h, --help            show this help message and exit
  --timeout TIMEOUT     Connection timeout
  --unit UNIT           Modbus device address
  --interval INTERVAL   Update interval
  --influx_host INFLUX_HOST
                        InfluxDB host
  --influx_port INFLUX_PORT
                        InfluxDB port
  --influx_db INFLUX_DB
                        InfluxDB database
  --influx_user INFLUX_USER
                        InfluxDB username
  --influx_pass INFLUX_PASS
                        InfluxDB password

Connecting

If you wish to use Modbus TCP the following parameters are relevant:

host = IP or DNS name of your Modbus TCP device, required
port = TCP port of the Modbus TCP device, required
unit = Modbus device address, default=1, optional

While if you are using a Modbus RTU connection you can specify:

device = path to serial device, e.g. /dev/ttyUSB0, required
baud = baud rate of your device, defaults to product default, optional
unit = Modbus device address, defaults to 1, optional

Connecting to the inverter:

    >>> import solaredge_modbus

    # Inverter over Modbus TCP
    >>> inverter = solaredge_modbus.Inverter(host="10.0.0.123", port=1502)
    
    # Inverter over Modbus RTU
    >>> inverter = solaredge_modbus.Inverter(device="/dev/ttyUSB0", baud=115200)

Test the connection, remember that only a single connection at a time is allowed:

    >>> inverter.connect()
    True

    >>> inverter.connected()
    True

While it is not necessary to explicitly call connect() before reading registers, you should do so before calling connected(). The connection can be closed by calling disconnect().

Printing the class yields basic device parameters:

    >>> inverter
    Inverter(10.0.0.123:1502, connectionType.TCP: timeout=1, retries=3, unit=0x1)

Reading Registers

Reading a single input register by name:

    >>> inverter.read("current")
    {
        'current': 895
    }

Read all input registers using read_all():

    >>> inverter.read_all()
    {
        'c_manufacturer': 'SolarEdge',
        'c_model': 'SE3500H-RW000BNN4',
        'c_version': '0004.0009.0030',
        'c_serialnumber': '123ABC12',
        'c_deviceaddress': 1,
        'c_sunspec_did': 101,
        'current': 895,
        'l1_current': 895,
        'l2_current': False,
        'l3_current': False,
        'current_scale': -2,
        'l1_voltage': 2403,
        'l2_voltage': False,
        'l3_voltage': False,
        'l1n_voltage': False,
        'l2n_voltage': False,
        'l3n_voltage': False,
        'voltage_scale': -1,
        'power_ac': 21413,
        'power_ac_scale': -1, 
        'frequency': 50003,
        'frequency_scale': -3,
        'power_apparent': 21479,
        'power_apparent_scale': -1,
        'power_reactive': 16859,
        'power_reactive_scale': -2,
        'power_factor': 9969,
        'power_factor_scale': -2,
        'energy_total': 3466757,
        'energy_total_scale': 0,
        'current_dc': 5678,
        'current_dc_scale': -3,
        'voltage_dc': 3826,
        'voltage_dc_scale': -1,
        'power_dc': 21726,
        'power_dc_scale': -1,
        'temperature': 4979,
        'temperature_scale': -2,
        'status': 4,
        'vendor_status': 0
    }

Register Details

If you need more information about a particular register, to look up the units or enumerations, for example:

    >>> inverter.registers["current"]
        # address, length, type, datatype, valuetype, name, unit, batching
        (
            40071, 
            1, 
            <registerType.HOLDING: 2>, 
            <registerDataType.UINT16: 3>, 
            <class 'int'>, 
            'Current', 
            'A', 
            2
        )

    >>> inverter.registers["status"]
        # address, length, type, datatype, valuetype, name, unit, batching
        (
            40107, 
            1, 
            <registerType.HOLDING: 2>, 
            <registerDataType.UINT16: 3>, 
            <class 'int'>, 
            'Status', 
            ['Undefined', 'Off', 'Sleeping', 'Grid Monitoring', 'Producing', 'Producing (Throttled)', 'Shutting Down', 'Fault', 'Standby'], 
            2
        )

Multiple Inverters

If you have multiple inverters connected together over the RS485 bus, you can query the individual inverters using Modbus RTU or Modbus TCP by instantiating multiple inverter objects:

    # Master inverter over Modbus TCP
    >>> master = solaredge_modbus.Inverter(host="10.0.0.123", port=1502, unit=1)

    # Second inverter using master's connection
    >>> second = solaredge_modbus.Inverter(parent=master, unit=2)

    # Third inverter
    >>> third = solaredge_modbus.Inverter(parent=master, unit=3)

Meters & Batteries

SolarEdge supports various kWh meters and batteries, and exposes their registers through a set of pre-defined registers on the inverter. The number of supported registers is hard-coded, per the SolarEdge SunSpec implementation, to three meters and two batteries. It is possible to query their registers:

    >>> inverter.meters()
    {
        'Meter1': Meter1(10.0.0.123:1502, connectionType.TCP: timeout=1, retries=3, unit=0x1)
    }

    >>> meter1 = inverter.meters()["Meter1"]
    >>> meter1
    Meter1(10.0.0.123:1502, connectionType.TCP: timeout=1, retries=3, unit=0x1)

    >>> meter1.read_all()
    {
        'c_manufacturer': 'SolarEdge',
        'c_model': 'PRO380-Mod',
        'c_option': 'Export+Import',
        'c_version': '2.19',
        'c_serialnumber': '12312332',
        'c_deviceaddress': 1,
        'c_sunspec_did': 203,
        'current': -13,
        ...
    }

Or similarly for batteries:

    >>> inverter.batteries()
    {
        'Battery1': Battery(10.0.0.123:1502, connectionType.TCP: timeout=1, retries=3, unit=0x1)
    }

    >>> battery1 = inverter.batteries()["Battery1"]
    >>> battery1
    Battery1(10.0.0.123:1502, connectionType.TCP: timeout=1, retries=3, unit=0x1)

    >>> battery1.read_all()
    {
        ...
    }

Calling meters() or batteries() on an inverter object is the recommended way of instantiating their objects. This way, checking for available devices, register offsetting, and sharing of the pymodbus connection is taken care of. If you want to to create a meter or battery object independently, do the following:

    # Meter #1 via the existing inverter connection
    >>> meter1 = solaredge_modbus.Meter(parent=inverter, offset=0)

    # Meter #2 over Modbus TCP, without a parent connection
    >>> meter2 = solaredge_modbus.Meter(host="10.0.0.123", port=1502, offset=1)

    # Battery #1 via the existing inverter connection
    >>> battery1 = solaredge_modbus.Battery(parent=inverter, offset=0)

    # Battery #1 over Modbus TCP, without a parent connection
    >>> battery1 = solaredge_modbus.Battery(host="10.0.0.123", port=1502, offset=1)

There are two points to consider when doing this. You will need to manually pass the parent and offset parameters, which take care of sharing an existing Modbus connection, and set the correct register addresses. Use offset 0 for the first device, 1 for the second, and 2 for the third. If you do not pass a parent inverter object, you will need to supply connection parameters just like those required by the inverter object. Remember that a second Modbus TCP or Modbus RTU connection will fail when already in use by another inverter, meter, or battery object.

Note: as I do not have access to a compatible kWh meter nor battery, this implementation is not thoroughly tested. If you have issues with this functionality, please open a GitHub issue.

Contributing

Contributions are more than welcome.

Note that the project description data, including the texts, logos, images, and/or trademarks, for each open source project belongs to its rightful owner. If you wish to add or remove any projects, please contact us at [email protected].